Highwall Error Codes

Back Home

E1

Back Home

Indoor ambient temp sensor fault

E2

Back Home

Indoor pipe temp sensor fault

E4

Back Home

Indoor PCB EEPROM fault

E5

Back Home

Indoor frozen / Indoor anti-frosting protection

E7

Back Home

Communication fault between indoor and outdoor unit

E9

Back Home

Indoor thermal overload / Indoor unit overload protection

E14

Back Home

Indoor motor feedback circuit fault

F1

Back Home

Outdoor IPM fault

F2

Back Home

Compressor start failure

F3

Back Home

Communication fault between outdoor PCB and power module

F4

Back Home

Compressor Exhaust temp overtop protection

F5

Back Home

Module thermal overload

F6

Back Home

Outdoor Ambient sensor fault

F7

Back Home

Outdoor Suction sensor fault

F8

Back Home

Outdoor DC fan motor fault

F9

Back Home

MCU reset

F10

Back Home

Malfunction of liquid pipe temp. sensor for indoor unit A

F11

Back Home

Loss of synchronism detection (compressor)

F12

Back Home

Outdoor PCB EEPROM fault

F13

Back Home

Lack of refrigerant or discharging

F14

Back Home

Four-way-valve couldn't shift normally

F15

Back Home

Terminal block temp too high

F16

Back Home

Malfunction of liquid pipe temp. sensor for indoor unit B

F17

Back Home

Malfunction of liquid pipe temp. sensor for indoor unit C

F18

Back Home

Malfunction of liquid pipe temp. sensor for indoor unit D

F19

Back Home

Unreliable utility power input

F20

Back Home

Compressor overload protection

F21

Back Home

Outdoor Defrost sensor fault

F22

Back Home

Outdoor Alternating current over current protection

F23

Back Home

Module input overcurrent

F24

Back Home

Module current detect circuit malfunction

F25

Back Home

Outdoor Exhaust sensor fault

F26

Back Home

Malfunction of gas pipe temp. sensor for indoor unit E

F27

Back Home

Compressor blocked or instantaneous stop

F28

Back Home

Position detection circuit fault of compressor

F29

Back Home

Malfunction of gas pipe temp. sensor for indoor unit A

F30

Back Home

Outdoor Suction temp overtop / Malfunction of gas pipe temp. sensor for indoor unit B

F31

Back Home

Malfunction of gas pipe temp. sensor for indoor unit C

F32

Back Home

Malfunction of gas pipe temp. sensor for indoor unit D

F33

Back Home

Malfunction of liquid pipe temp. sensor for indoor unit E

F34

Back Home

Outdoor pipe temp protection in cooling mode

F35

Back Home

Malfunction of module temp.sensor / Momentary power failure detection

F36

Back Home

Malfunction of condensing temp. sensor

F38

Back Home

Malfunction of Toci temp. sensor

F39

Back Home

System high pressure switch off

F40

Back Home

System low pressure switch off

F41

Back Home

System high pressure protection / Refrigerant overabundance / High condensing temp. / malfunction of fan motor.

F42

Back Home

System low pressure protection / Refrigerant shortage / Low defrosting temp. / malfunction of fan motor.

F43

Back Home

Wrong match between indoor unit and outdoor unit

Single Zone FlexFit Outdoor

Back Home

1 LED Flash

Back Home

Outdoor PCB EEPROM fault

2 LED Flashes

Back Home

Outdoor IPM fault

3 LED Flashes

Back Home

Outdoor Alternating current over current protection

4 LED Flashes

Back Home

Communication fault between outdoor PCB and power module

5 LED Flashes

Back Home

Compressor overload protection

6 LED Flashes

Back Home

Unreliable utility power input

7 LED Flashes

Back Home

Compressor blocked or instantaneous stop

8 LED Flashes

Back Home

Compressor Exhaust temp overtop protection

9 LED Flashes

Back Home

Outdoor DC fan motor fault

10 LED Flashes

Back Home

Outdoor Defrost sensor fault

11 LED Flashes

Back Home

Outdoor Suction sensor fault

12 LED Flashes

Back Home

Outdoor Ambient sensor fault

13 LED Flashes

Back Home

Outdoor Exhaust sensor fault

14 LED Flashes

Back Home

Outdoor Suction temp overtop

15 LED Flashes

Back Home

Communication fault between indoor and outdoor unit

16 LED Flashes

Back Home

Lack of refrigerant or discharging

17 LED Flashes

Back Home

Four-way-valve couldn't shift normally

18 LED Flashes

Back Home

Loss of synchronism detection (compressor)

19 LED Flashes

Back Home

Position detection circuit fault of compressor

20 LED Flashes

Back Home

Terminal block temp too high

21 LED Flashes

Back Home

Indoor unit overload protection

22 LED Flashes

Back Home

Indoor anti-frosting protection

24 LED Flashes

Back Home

Compressor start failure

25 LED Flashes

Back Home

Module input overcurrent

37 LED Flashes

Back Home

Outdoor pipe temp protection in cooling mode

46 LED Flashes

Back Home

Wrong match between indoor unit and outdoor unit

Multi Zone FlexFit Outdoor

Back Home

LED Disp. 1

Back Home

Outdoor PCB EEPROM fault

LED Disp. 2

Back Home

Outdoor IPM fault

LED Disp. 4

Back Home

Communication fault between outdoor PCB and power module

LED Disp. 5

Back Home

Compressor overload protection

LED Disp. 6

Back Home

Unreliable utility power input

LED Disp. 8

Back Home

Compressor Exhaust temp overtop protection

LED Disp. 9

Back Home

Outdoor DC fan motor fault

LED Disp. 10

Back Home

Outdoor Defrost sensor fault

LED Disp. 11

Back Home

Outdoor Suction sensor fault

LED Disp. 12

Back Home

Outdoor Ambient sensor fault

LED Disp. 13

Back Home

Outdoor Exhaust sensor fault

LED Disp. 15

Back Home

Communication fault between indoor and outdoor unit

LED Disp. 16

Back Home

Lack of refrigerant or discharging

LED Disp. 17

Back Home

Four-way-valve couldn't shift normally

LED Disp. 18

Back Home

Loss of synchronism detection (compressor)

LED Disp. 20

Back Home

Indoor thermal overload

LED Disp. 21

Back Home

Indoor frosted

LED Disp. 23

Back Home

Module thermal overload

LED Disp. 24

Back Home

Compressor start failure

LED Disp. 25

Back Home

Module input overcurrent

LED Disp. 26

Back Home

MCU reset

LED Disp. 27

Back Home

Module current detect circuit malfunction

LED Disp. 28

Back Home

Malfunction of liquid pipe temp. sensor for indoor unit A

LED Disp. 29

Back Home

Malfunction of liquid pipe temp. sensor for indoor unit B

LED Disp. 30

Back Home

Malfunction of liquid pipe temp. sensor for indoor unit C

LED Disp. 31

Back Home

Malfunction of liquid pipe temp. sensor for indoor unit D

LED Disp. 32

Back Home

Malfunction of gas pipe temp. sensor for indoor unit A

LED Disp. 33

Back Home

Malfunction of gas pipe temp. sensor for indoor unit B

LED Disp. 34

Back Home

Malfunction of gas pipe temp. sensor for indoor unit C

LED Disp. 35

Back Home

Malfunction of gas pipe temp. sensor for indoor unit D

LED Disp. 36

Back Home

Malfunction of gas pipe temp. sensor for indoor unit E

LED Disp. 38

Back Home

Malfunction of module temp.sensor Momentary power failure detection

LED Disp. 39

Back Home

Malfunction of condensing temp. sensor

LED Disp. 40

Back Home

Malfunction of liquid pipe temp. sensor for indoor unit E

LED Disp. 41

Back Home

Malfunction of ‘Toci’temp. sensor

LED Disp. 42

Back Home

System high pressure switch off

LED Disp. 43

Back Home

System low pressure switch off

LED Disp. 44

Back Home

System high pressure protection.Refrigerant overabundance, High condensing temp. or malfunction of fan motor.

LED Disp. 45

Back Home

System low pressure protection.Refrigerant shortage, Low defrosting temp., or malfunction of fan motor.

Single and 2 Zone Multi 2U18 FlexFit Outdoor

Back Home

LED Disp. 1

Back Home

Outdoor PCB EEPROM fault

LED Disp. 2

Back Home

Outdoor IPM fault

LED Disp. 3

Back Home

Outdoor Alternating current over current protection / Outdoor current protection

LED Disp. 4

Back Home

Communication fault between outdoor PCB and power module

LED Disp. 5

Back Home

Compressor overload protection

LED Disp. 6

Back Home

Unstable utility power input

LED Disp. 7

Back Home

Compressor blocked or instantaneous stop

LED Disp. 8

Back Home

Compressor Exhaust temp overtop protection

LED Disp. 9

Back Home

Outdoor DC fan motor fault

LED Disp. 10

Back Home

Outdoor Defrost sensor fault

LED Disp. 11

Back Home

Outdoor Suction sensor fault

LED Disp. 12

Back Home

Outdoor Ambient sensor fault

LED Disp. 13

Back Home

Outdoor Exhaust sensor fault

LED Disp. 14

Back Home

Outdoor Suction temp overtop

LED Disp. 15

Back Home

Communication fault between indoor and outdoor unit

LED Disp. 16

Back Home

Lack of refrigerant or discharging / Low refrigerant

LED Disp. 17

Back Home

Four-way-valve couldn't shift normally / failure

LED Disp. 18

Back Home

Loss of synchronism detection (compressor)

LED Disp. 19

Back Home

Position detection circuit fault of compressor

LED Disp. 20

Back Home

Terminal block temp too high

LED Disp. 21

Back Home

Indoor unit overload protection

LED Disp. 22

Back Home

Indoor anti-frosting protection

LED Disp. 24

Back Home

Compressor start failure

LED Disp. 25

Back Home

Module input voltage overcurrent

LED Disp. 37

Back Home

Outdoor pipe temp protection in cooling mode

LED Disp. 46

Back Home

Wrong match between indoor unit and outdoor unit

Cassette Error Codes

Back Home

2Y/1G

Back Home

Outdoor PCB EEPROM fault

2Y/2G

Back Home

Outdoor IPM fault

2Y/3G

Back Home

Outdoor Alternating current over current protection

2Y/4G

Back Home

Communication fault between outdoor PCB and power module

2Y/5G

Back Home

Compressor overload protection

2Y/6G

Back Home

Unreliable utility power input

2Y/7G

Back Home

Compressor blocked or instantaneous stop

2Y/8G

Back Home

Compressor Exhaust temp overtop protection

2Y/9G

Back Home

Outdoor DC fan motor fault

3Y/0G

Back Home

Outdoor Defrost sensor fault

3Y/1G

Back Home

Outdoor Suction sensor fault

3Y/2G

Back Home

Outdoor Ambient sensor fault

3Y/3G

Back Home

Outdoor Exhaust sensor fault

3Y/4G

Back Home

Outdoor Suction temp overtop

3Y/5G

Back Home

Communication fault between indoor and outdoor unit

3Y/6G

Back Home

Lack of refrigerant or discharging

3Y/7G

Back Home

Four-way-valve couldn't shift normally

3Y/8G

Back Home

Loss of synchronism detection (compressor)

3Y/9G

Back Home

Position detection circuit fault of compressor

4Y/0G

Back Home

Terminal block temp too high or
Indoor thermal overload

4Y/1G

Back Home

Indoor unit overload protection or
Indoor frosted

4Y/2G

Back Home

Indoor anti-frosting protection

4Y/3G

Back Home

Module thermal overload

4Y/4G

Back Home

Compressor start failure

4Y/5G

Back Home

Module input overcurrent

4Y/6G

Back Home

MCU reset

4Y/7G

Back Home

Module current detect circuit malfunction

4Y/8G

Back Home

Malfunction of liquid pipe temp. sensor for indoor unit A

4Y/9G

Back Home

Malfunction of liquid pipe temp. sensor for indoor unit B

5Y/0G

Back Home

Malfunction of liquid pipe temp. sensor for indoor unit C

5Y/1G

Back Home

Malfunction of liquid pipe temp. sensor for indoor unit D

5Y/2G

Back Home

Malfunction of gas pipe temp. sensor for indoor unit A

5Y/3G

Back Home

Malfunction of gas pipe temp. sensor for indoor unit B

5Y/4G

Back Home

Malfunction of gas pipe temp. sensor for indoor unit C

5Y/5G

Back Home

Malfunction of gas pipe temp. sensor for indoor unit D

5Y/6G

Back Home

Malfunction of gas pipe temp. sensor for indoor unit E

5Y/7G

Back Home

Outdoor pipe temp protection in cooling mode

5Y/8G

Back Home

Malfunction of module temp.sensor / Momentary power failure detection

5Y/9G

Back Home

Malfunction of condensing temp. sensor

6Y/0G

Back Home

Malfunction of liquid pipe temp. sensor for indoor unit E

6Y/1G

Back Home

Malfunction of ‘Toci’temp. sensor

6Y/2G

Back Home

System high pressure switch off

6Y/3G

Back Home

System low pressure switch off

6Y/4G

Back Home

System high pressure protection.Refrigerant overabundance / High condensing temp. or malfunction of fan motor.

6Y/5G

Back Home

System low pressure protection.Refrigerant shortage / Low defrosting temp., or malfunction of fan motor.

6Y/6G

Back Home

Wrong match between indoor unit and outdoor unit

Wired Hex Disp.

Back Home

15

Back Home

Outdoor PCB EEPROM fault

16

Back Home

Outdoor IPM fault

17

Back Home

Outdoor Alternating current over current protection

18

Back Home

Communication fault between outdoor PCB and power module

19

Back Home

Compressor overload protection

1A

Back Home

Unreliable utility power input

1B

Back Home

Compressor blocked or instantaneous stop

1C

Back Home

Compressor Exhaust temp overtop protection

1D

Back Home

Outdoor DC fan motor fault

1E

Back Home

Outdoor Defrost sensor fault

1F

Back Home

Outdoor Suction sensor fault

20

Back Home

Outdoor Ambient sensor fault

21

Back Home

Outdoor Exhaust sensor fault

22

Back Home

Outdoor Suction temp overtop

23

Back Home

Communication fault between indoor and outdoor unit

24

Back Home

Lack of refrigerant or discharging

25

Back Home

Four-way-valve couldn't shift normally

26

Back Home

Loss of synchronism detection (compressor)

27

Back Home

Position detection circuit fault of compressor

28

Back Home

Terminal block temp too high


Indoor thermal overload

29

Back Home

Indoor unit overload protection


Indoor frosted

2A

Back Home

Indoor anti-frosting protection

2B

Back Home

Module thermal overload

2C

Back Home

Compressor start failure

2D

Back Home

Module input overcurrent

2E

Back Home

MCU reset

2F

Back Home

Module current detect circuit malfunction

30

Back Home

Malfunction of liquid pipe temp. sensor for indoor unit A

31

Back Home

Malfunction of liquid pipe temp. sensor for indoor unit B

32

Back Home

Malfunction of liquid pipe temp. sensor for indoor unit C

33

Back Home

Malfunction of liquid pipe temp. sensor for indoor unit D

34

Back Home

Malfunction of gas pipe temp. sensor for indoor unit A

35

Back Home

Malfunction of gas pipe temp. sensor for indoor unit B

36

Back Home

Malfunction of gas pipe temp. sensor for indoor unit C

37

Back Home

Malfunction of gas pipe temp. sensor for indoor unit D

38

Back Home

Malfunction of gas pipe temp. sensor for indoor unit E

39

Back Home

Outdoor pipe temp protection in cooling mode

3A

Back Home

Malfunction of module temp.sensor / Momentary power failure detection

3B

Back Home

Malfunction of condensing temp. sensor

3C

Back Home

Malfunction of liquid pipe temp. sensor for indoor unit E

3D

Back Home

Malfunction of ‘Toci’temp. sensor

3E

Back Home

System high pressure switch off

3F

Back Home

System low pressure switch off

40

Back Home

System high pressure protection.Refrigerant overabundance / High condensing temp. or malfunction of fan motor.

41

Back Home

System low pressure protection.Refrigerant shortage / Low defrosting temp., or malfunction of fan motor.

42

Back Home

Wrong match between indoor unit and outdoor unit

Common Errors

Back Home

E1

Back Home

Indoor pipe temp sensor fault

Is the sensor properly plugged onto board?

Yes No

View as PDF

E1

Back Home

Indoor pipe temp sensor fault

Unplug sensor. Is it reading properly? 11KΩ @ 72°F 30KΩ @ 32°F

Yes Back No

E1

Back Home

Indoor pipe temp sensor fault

Are the pins on the board and the sensor connector free of corrosion or defect?

Yes Back No

E1

Back Home

Indoor pipe temp sensor fault

Replace board.

Back

E1

Back Home

Indoor pipe temp sensor fault

Fix connection.

Back

E1

Back Home

Indoor pipe temp sensor fault

Replace sensor.

Back

E1

Back Home

Indoor pipe temp sensor fault

Rehab the connector if possible. Replace sensor and/or board if needed.

Back

E5

Back Home

Frosted indoor coil

Is the indoor coil sensor in place?

Yes No

View as PDF

E5

Back Home

Frosted indoor coil

Is the coil sensor reading properly? Unplug off board. 11KΩ @ 72°F 30KΩ @ 32°F

Yes Back No

E5

Back Home

Frosted indoor coil

Is air flowing properly? If unit is ducted is the duct designed per design spec?

Yes Back No

E5

Back Home

Frosted indoor coil

Does the system have a refrigerant leak?

Yes Back No

E5

Back Home

Frosted indoor coil

Repair and recharge system.

Back

E5

Back Home

Frosted indoor coil

Adjust or replace EEV coil.

Back

E5

Back Home

Frosted indoor coil

Is the unit oversized for the room?

Yes Back No

E5

Back Home

Frosted indoor coil

Downsize unit.

Back

E5

Back Home

Frosted indoor coil

Fix placement.

Back

E5

Back Home

Frosted indoor coil

Replace sensor.

Back

E5

Back Home

Frosted indoor coil

Unblock or adjust air flow.

Back

E5

Back Home

Frosted indoor coil

Is EEV coil out of position or have an open coil? Read 46Ω Red->Violet Red->Yellow Red->Orange Red->Blue

Yes Back No

E5

Back Home

Frosted indoor coil

Is indoor ambient air sensor reading properly? 11KΩ @ 72°F 30KΩ @ 32°F

Yes Back No

E5

Back Home

Frosted indoor coil

Replace ambient sensor.

Back

E5

Back Home

Frosted indoor coil

Replace indoor PCB.

Back

E7

Back Home

Communication failure.

The connecting wiring between the outdoor and indoor units should be 14-4 (14 gauge 4 conductor) SOOW cable. It is recommended that the wire connections be made with spade terminals. If spade terminals are not used then the wires should not be twisted prior to connecting to the screw terminals. All strands of the wires need to be tightened to the terminal with no fraying. The cable should be secured with the strain relief clamp.

Next

View as PDF

E7

Back Home

Communication failure.

Disconnect power to outdoor unit for 10 minutes. Does issue return after 3 minutes?

Yes Back No

E7

Back Home

Communication failure.

Is the LED on the outdoor PCB flashing?

Yes Back No

E7

Back Home

Communication failure.

Is the LED on the indoor PCB flashing?

Yes Back No

E7

Back Home

Communication failure.

Check wires and wire connections.

Back

E7

Back Home

Communication failure.

Check wires and wire connections.

Back

E7

Back Home

Communication failure.

Replace outdoor PCB

Back

E7

Back Home

Communication failure.

Replace outdoor PCB

Back

F3

Back Home

Outdoor internal communication error

This error occurs when the outdoor PCB looses communication with the Inverter Power module (IPM).

Next

View as PDF

F3

Back Home

Outdoor internal communication error

Is the communication wire connected properly onto CN11 on IPM board and CN24 on PCB?

Yes Back No

F3

Back Home

Outdoor internal communication error

Is the low volt wire connected properly onto CN10 on IPM board and CN23 on PCB?

Yes Back No

F3

Back Home

Outdoor internal communication error

Unplug CN10 on IPM. Is there 5VDC on wires at pins 1-2 and 15VDC on wires at pins 2-3?

Yes Back No

F3

Back Home

Outdoor internal communication error

Replace IPM.

Back

F3

Back Home

Outdoor internal communication error

Fix connection.

Back

F3

Back Home

Outdoor internal communication error

Fix connection.

Back

F3

Back Home

Outdoor internal communication error

Replace PCB

Back

F5

Back Home

Inverter power module (IPM) over current

Is supply voltage correct? Are the wire connections to IPM and compressor correct per wire diagram? Is the insulation of the wires good?

Yes No

View as PDF

F5

Back Home

Inverter power module (IPM) over current

Are the compressor windings shorted/grounded?

Yes Back No

F5

Back Home

Inverter power module (IPM) over current

Replace compressor.

Back

F5

Back Home

Inverter power module (IPM) over current

Correct the wiring.

Back

F5

Back Home

Inverter power module (IPM) over current

Replace IPM.

Back

F7

Back Home

Outdoor Suction Sensor Fault

Is the sensor properly plugged onto board?

Yes No

View as PDF

F7

Back Home

Outdoor Suction Sensor Fault

Unplug sensor. Is it reading properly? 11KΩ @ 72°F 30KΩ @ 32°F

Yes Back No

F7

Back Home

Outdoor Suction Sensor Fault

Are the pins on the board and the sensor connector free of corrosion or defect?

Yes Back No

F7

Back Home

Outdoor Suction Sensor Fault

Replace board.

Back

F7

Back Home

Outdoor Suction Sensor Fault

Fix connection.

Back

F7

Back Home

Outdoor Suction Sensor Fault

Replace sensor.

Back

F7

Back Home

Outdoor Suction Sensor Fault

Rehab the connector if possible. Replace sensor and/or board if needed.

Back

F8

Back Home

Outdoor Fan Motor Fault

Power off the unit and gain access to outdoor PCB. Locate the fan motor wires on board, don’t unplug. Use meter to check for voltage.

Ok

View as PDF

F8

Back Home

Outdoor Fan Motor Fault

Are the following volts present when power is turned on? Black to Red ~ 300VDC Black to White ~ 15VDC

Yes Back No

F8

Back Home

Outdoor Fan Motor Fault

After about 3 minutes, volts here? Black to Yellow ~ 1-4VDC

Yes Back No

F8

Back Home

Outdoor Fan Motor Fault

Is the fan running?

Yes Back No

F8

Back Home

Outdoor Fan Motor Fault

Volts here? Black to Blue ~ 8VAC

Yes Back No

F8

Back Home

Outdoor Fan Motor Fault

Replace PCB

Back

F8

Back Home

Outdoor Fan Motor Fault

Replace PCB

Back

F8

Back Home

Outdoor Fan Motor Fault

Replace PCB

Back

F8

Back Home

Outdoor Fan Motor Fault

Replace fan motor

Back

F8

Back Home

Outdoor Fan Motor Fault

Replace fan motor

Back

F11

Back Home

Loss of Compressor Synchronization

Locate and note the wire colors on the U,V,W terminals of the Inverter Board. 3U24/4U36: U–Red V–White W–Black. Single zone units: U–Black V–White W–Red

Ok

View as PDF

F11

Back Home

Loss of Compressor Synchronization

Are the wires on the correct terminals?

Yes Back No

F11

Back Home

Loss of Compressor Synchronization

Unplug wires off board. Do all 3 wires ohm properly? Red & White = Red & Black = Black & White?

Yes Back No

F11

Back Home

Loss of Compressor Synchronization

Does each wire ohm open to ground?

Yes Back No

F11

Back Home

Loss of Compressor Synchronization

Call Tech Line 866-814-3633 option 3

Back

F11

Back Home

Loss of Compressor Synchronization

Fix according to above note.

Back

F11

Back Home

Loss of Compressor Synchronization

Replace compressor

Back

F11

Back Home

Loss of Compressor Synchronization

Replace compressor

Back

F12

Back Home

Outdoor EEPROM failure

Disconnect power, wait 10 minutes and power back on. Does error return?

Yes No

View as PDF

F12

Back Home

Outdoor EEPROM failure

Replace outdoor main board.

Back

F12

Back Home

Outdoor EEPROM failure

Take no further action.

Back

F13

Back Home

Lack of Refrigerant

Error in heat or cool?

Heat Cool

View as PDF

F13

Back Home

Lack of Refrigerant

Is compressor amp draw between 0.6-1.6 Amps when both of the following is correct? *ID coil temp minus ID ambient ≤41°F *Both ID & OD ambient temps are between 44~73°F

Yes Back No

F13

Back Home

Lack of Refrigerant

Is compressor amp draw between 0.6-1.6 Amps when both of the following is correct? *ID ambient minus ID coil temp ≤39°F *Both ID & OD ambient temps ≥77°F

Yes Back No

F13

Back Home

Lack of Refrigerant

Find and repair leak

Back

F13

Back Home

Lack of Refrigerant

Unplug each sensor. Is it reading properly? 11KΩ @ 72°F 30KΩ @ 32°F

Yes Back No

F13

Back Home

Lack of Refrigerant

Replace sensor.

Back

F13

Back Home

Lack of Refrigerant

Are the pins on the board and the sensor connector free of corrosion or defect?

Yes Back No

F13

Back Home

Lack of Refrigerant

Replace board.

Back

F13

Back Home

Lack of Refrigerant

Rehab the connector if possible. Replace sensor and/or board if needed.

Back

F39

Back Home

Open High Pressure Switch

Is high pressure switch connected to main board

Yes No

View as PDF

F39

Back Home

Open High Pressure Switch

Unplug connector. Is pressure switch open?

Yes Back No

F39

Back Home

Open High Pressure Switch

Is system pressure higher than switch open limit?

Yes Back No

F39

Back Home

Open High Pressure Switch

Are the indoor coils heating/cooling?

Yes Back No

F39

Back Home

Open High Pressure Switch

Is the outdoor unit installed too close to walls or are the coils blocked?

Yes Back No

F39

Back Home

Open High Pressure Switch

Replace EEV coil.

Back

F39

Back Home

Open High Pressure Switch

Is the outdoor unit installed too close to walls or are the coils blocked?

Yes Back No

F39

Back Home

Open High Pressure Switch

Fix install or clean coil.

Back

F39

Back Home

Open High Pressure Switch

Reconnect.

Back

F39

Back Home

Open High Pressure Switch

Replace PCB.

Back

F39

Back Home

Open High Pressure Switch

Replace limit switch.

Back

F39

Back Home

Open High Pressure Switch

Replace limit switch.

Back

F39

Back Home

Open High Pressure Switch

Is EEV coil out of position or have an open coil? Read 46Ω Red->Violet Red->Yellow Red->Orange Red->Blue

Yes Back No

F39

Back Home

Open High Pressure Switch

Replace PCB.

Back

F39

Back Home

Open High Pressure Switch

Unit is overcharged. Recover and recharge system.

Back

F40

Back Home

Open Low Pressure Switch

Is low pressure switch connected to main board

Yes No

View as PDF

F40

Back Home

Open Low Pressure Switch

Unplug connector. Is pressure switch open?

Yes Back No

F40

Back Home

Open Low Pressure Switch

Is system pressure lower than switch open limit?

Yes Back No

F40

Back Home

Open Low Pressure Switch

Are the indoor coils heating/cooling?

Yes Back No

F40

Back Home

Open Low Pressure Switch

Unit is low on refrigerant. Check for leaks. Weigh out current charge, fix and recharge system.

Back

F40

Back Home

Open Low Pressure Switch

Replace EEV coil.

Back

F40

Back Home

Open Low Pressure Switch

Reconnect.

Back

F40

Back Home

Open Low Pressure Switch

Replace PCB.

Back

F40

Back Home

Open Low Pressure Switch

Replace limit switch.

Back

F40

Back Home

Open Low Pressure Switch

Replace limit switch.

Back

F40

Back Home

Open Low Pressure Switch

Is EEV coil out of position or have an open coil? Read 46Ω Red->Violet Red->Yellow Red->Orange Red->Blue

Yes Back No

F40

Back Home

Open Low Pressure Switch

Replace PCB.

Back

F40

Back Home

Open Low Pressure Switch

Recover and recharge system.

Back

Haier Ductless

Back Home

Multi Zone Calc

Back Home
Factory Charge: -oz.

The amount of refrigerant in the system from the factory.


Add to Factory Charge: -oz.

Amount of charge to add to the factory amount.


Add oz per ft: -oz.
The amount of refrigerant to be added/removed.

Total oz. Required: -oz.

Total amount of refrigerant needed in the system. Based off the total length of the system.



Length A:

Length of lineset on circuit A.

Length B:

Length of lineset on circuit B.

Length C:

Length of lineset on circuit C.

Length D:

Length of lineset on circuit D.

-

-

Total ft. of Lineset: -ft.

Combined length of each circuit. (A+B+C+D=Total)


Max Length: -ft.

The maximum length the lineset can be.


Max Length Before Adding: -ft.

The longest length of lineset before having to add refrigerant to the factory charge.


Max Length Single Circuit: -ft.

The longest length of lineset before having to add refrigerant to the factory charge.


Max Lift: -ft.

The maximum lift allowed between the outdoor unit and COMBINED indoor units is XX feet total of all installed units. For example, 3 units with 15 elevation each is 45 feet.


Single Zone Calc

Back Home
Factory Charge: -oz.

The amount of refrigerant in the system from the factory.


Add to Factory Charge: -oz.

Amount of charge to add to the factory amount.


Add oz per ft: -oz.

The amount of refrigerant to be added/removed.


Total oz. Required: -oz.

Total amount of refrigerant needed in the system. Based off the total length of the system.



Total Length:

Total length of lineset.

-

Total ft. of Lineset: -ft.

Total length of lineset.


Max Length: -ft.

The maximum length the lineset can be.


Max Length Before Adding: -ft.

The longest length of lineset before having to add refrigerant to the factory charge.


Videos

Back Home

Wall Mount

Cassette

Slim Duct

Outdoor Unit

FAQ

Back Home

1) Q: How do I change the display to read Fahrenheit? (It currently displays Celsius).

A: Locate the “Extra Function” and “Confirm/Cancel” buttons on the wireless remote. Press the “Power” button to turn the wireless remote “On”. While viewing the LCD display on the wireless remote, tap the “Extra Function” button multiple times until the temperature is displayed in °F. Immediately press the “Confirm/Cancel” button to lock in the selection. (The “Confirm/Cancel” button must be pressed within 5 seconds of reaching the desired selection; otherwise the remote will revert back to the previous setting).

2) Q: The temperature displayed on the wall unit shows a higher temperature than what my thermometer on the table does, why?

A: The unit is mounted high on the wall where air in the room is normally at a higher temperature, therefore, the reading will be higher.

3) Q: The indoor fan operates all the time when the system is in cool mode.

A: This is a normal operating condition. The indoor fan needs to be operating to draw air across the indoor unit sensor to determine the temperature of the room for cycling the outdoor unit on and off.

4) Q: How do I make the system operate in Fan mode?

A: Locate the “Extra Function” and “Confirm/Cancel” buttons on the wireless remote. Press the “Power” button to turn the wireless remote “On”. While viewing the LCD display on the wireless remote, tap the “Extra Function” button multiple times until the “Fan” icon is displayed. Immediately press the “Confirm/Cancel” button to lock in the selection. (The “Confirm/Cancel” button must be pressed within five seconds of reaching the desired selection; otherwise the remote will revert back to the previous setting). The system will now operate in “Fan” Mode.

5) Q: Is there a humidity percentage setting for Dry mode?

A: No. In Dry mode, the system will continually run at a reduced cooling speed to remove humidity without substantial cooling. It does not monitor humidity levels.

6) Q: On a multi-split system, can one indoor unit operate in Cool mode at the same time another indoor unit is operating in Heat mode, or vice versa?

A: No, the outdoor unit can provide only one mode of operation at a time. The first unit to turn on sets the mode the outdoor unit will operate at.

7) Q: What does the “Health” button on the remote do?

A: This feature is not applicable on systems sold in North America.

8) Q: There is an icon displayed on the indoor unit in the shape of Christmas tree, what does that indicate?

A: The icon indicates the “Health” button has been pressed. Press the “Health” button one time to turn the icon off. This function is not applicable on systems sold in North America.

9) Q: The wall unit display turns off after making a selection with the remote controller.

A: Press the “light” button on the remote control to return the wall unit display to being constantly lit. The “light” button feature is used to turn the wall unit display on and off. Most often used where the unit is installed in a bedroom area where a lit indicator may disturb sleep.

10) Q: Can the system be operated if I cannot find the remote controller?

A: Yes. Press the Emergency Run button with a non-metallic pen or pencil. It is in an opening underneath the unit cover on the right side of the cabinet. After the beep, the unit will maintain 75° until the remote is located. Refer to the owner’s manual for operation of this feature.

Efficiency Calculator

Back Home
 

Unit Information

SEER:

SEER rating of unit.

BTUH Capacity Cooling:

Cooling capacity of the unit for cooling in BTUH.

HSPF:

HSPF rating of unit.

BTUH Capacity Heating:

Cooling capacity of the unit for heating in BTUH.

kWH Cost:

kWH cost in cents.

Cost per year in cooling:

$

Cost per year in heating:

$


Click the button to email the results (will open your email client)